The Event Rental Diesel Generator delivers reliable, fuel-efficient power for demanding venues. Engineered for ultra-quiet operation and quick transport, it ensures seamless uptime that meets strict European and American emission standards.
Technical parameters
|
Technical Parameter |
ER-70T4F (70 kVA) |
ER-135T4F (135 kVA) |
ER-275T4F (275 kVA) |
|
ELECTRICAL PERFORMANCE |
|||
|
Prime Power (PRP) |
70 kVA / 56 kW |
135 kVA / 108 kW |
275 kVA / 220 kW |
|
Standby Power (ESP) |
77 kVA / 61.6 kW |
150 kVA / 120 kW |
300 kVA / 240 kW |
|
Rated Voltage (Selectable) |
480/277V | 240/120V |
480/277V | 240/120V |
480/277V | 240/120V |
|
Frequency / Power Factor |
60Hz / 0.8 PF |
60Hz / 0.8 PF |
60Hz / 0.8 PF |
|
Voltage Regulation |
±0.5% |
±0.5% |
±0.5% |
|
POWERTRAIN & EMISSIONS |
|||
|
Engine Brand & Model |
Cummins F3.8 |
John Deere 4045 |
Cummins QSB7-G5 |
|
Emission Certification |
US EPA Tier 4F / EU Stage V |
US EPA Tier 4F / EU Stage V |
US EPA Tier 4F / EU Stage V |
|
Aspiration Type |
Turbocharged & Charge Air Cooled |
Turbocharged & Charge Air Cooled |
Turbocharged & Charge Air Cooled |
|
Governor Type |
Electronic (Isochronous) |
Electronic (Isochronous) |
Electronic (Isochronous) |
|
Alternator Brand & Model |
Stamford S2L1D-C |
Stamford UCI274E |
Stamford S4L1D-D |
|
Insulation / Protection Class |
Class H / IP23 |
Class H / IP23 |
Class H / IP23 |
|
RENTAL & OPERATIONAL DATA |
|||
|
Sound Level (@ 7m / 23ft) |
≤ 63 dB(A) |
≤ 65 dB(A) |
≤ 67 dB(A) |
|
Fuel Tank Capacity (Bunded) |
380 L (100 gal) |
640 L (169 gal) |
1,150 L (303 gal) |
|
Fuel Consumption (100% Load) |
16.5 L/hr (4.3 gph) |
31.2 L/hr (8.2 gph) |
58.5 L/hr (15.4 gph) |
|
Fuel Consumption (75% Load) |
12.8 L/hr (3.4 gph) |
23.8 L/hr (6.3 gph) |
44.2 L/hr (11.6 gph) |
|
Runtime @ 75% Load |
≥ 29 Hours |
≥ 26 Hours |
≥ 26 Hours |
|
DEF (Urea) Tank Capacity |
25 L |
45 L |
70 L |
|
Maintenance Interval |
500 Hours |
500 Hours |
500 Hours |
|
LOGISTICS & ENCLOSURE |
|||
|
Dimensions (L × W × H) |
2,600 × 1,100 × 1,650 mm |
3,100 × 1,200 × 1,850 mm |
4,100 × 1,450 × 2,200 mm |
|
Dry Weight / Wet Weight |
1,650 kg / 2,050 kg |
2,450 kg / 3,100 kg |
4,200 kg / 5,400 kg |
|
Rigging Configuration |
4-Pt Tie Down / 1-Pt Lifting Eye |
4-Pt Tie Down / 1-Pt Lifting Eye |
4-Pt Tie Down / 1-Pt Lifting Eye |
|
Enclosure Material |
2.0mm Galvanized Steel |
2.0mm Galvanized Steel |
2.0mm Galvanized Steel |
Rental-Specific Engineering
110% Bunded Base: Fully self-contained footprint prevents site contamination from fuel, oil, or coolant leaks.
Multi-Voltage Switch: Heavy-duty selector allows rapid switching between 3-phase and single-phase configurations.
Cam-Lock Panel: Busbar design includes color-coded quick-connect receptacles for fast, tool-free cable hookups.
Four-Point Lift: Reinforced skid features integrated forklift pockets and a central overhead lifting eye.
Dual-Stage Filtration: Factory-fitted fuel-water separators protect the injection system during variable fuel quality supply.
External Fuel Fill: Lockable, spill-proof access point enables safe refueling without opening the main enclosure.
Powertrain & Emissions
Tier 4F/Stage V Engine
Equipped with certified diesel engines meeting current US EPA and EU emission limits.
DEF Injection System
Integrated Diesel Exhaust Fluid dosing lowers NOx emissions without sacrificing engine mechanical efficiency.
Electronic Common-Rail
High-pressure fuel injection optimizes combustion parameters for variable load profiles.
DOC & DPF Filtration
Maintenance-free Diesel Oxidation Catalyst reduces particulate matter under low-load event conditions.
Smart Regeneration
Automated exhaust system cleaning operates seamlessly without interrupting onsite power delivery.
Applications
|
Application Field |
How It Was Used |
Benefits |
|
Outdoor Festivals |
Powers main stages and lighting rigs. |
Stable voltage prevents sound distortion. |
|
Corporate Events |
Supplies energy to temporary HVAC systems. |
Ultra-quiet operation maintains quiet atmosphere. |
|
Live Broadcasting |
Provides primary power for media trucks. |
Parallel configuration ensures uninterrupted transmission. |
|
Sports Stadiums |
Backs up field floodlights and displays. |
Instant breaker trip protects electronics. |
|
Disaster Relief |
Energizes emergency medical tents and camps. |
Quick cam-lock connection speeds deployment. |
Quality Control & FAT
120% Overload Test: 2-hour full load operation guarantees structural thermal stability under extreme peak demands.
0.25% Voltage Regulation: Transient load testing ensures absolute voltage stability to protect sensitive event electronics.
65 dB(A) Sound Verification: Acoustic chamber testing at 7 meters proves superior enclosure insulation and low-noise compliance.
100% Micro-Crack Detection: Ultrasonic welding inspection ensures zero structural defects under long-distance rental transport vibrations.
IP54 Enclosure Rating: High-pressure water spray validation confirms dustproof and waterproof durability in heavy storms.
4-Hour Continuous Run: Factory steady-state testing verifies zero fluid leakage and flawless control module synchronization.