Product Overview
Hospital Medical Equipment Diesel Generator designed for MRI systems, CT scanners, ventilators, laboratory analyzers, and critical hospital electrical equipment, featuring stable voltage recovery, low harmonic output, and ≤10s automatic emergency startup during utility failure.
Technical Specifications
|
Item |
Specification |
|
Power Range |
50–2500kVA |
|
Rated Voltage |
220V / 380V / 400V / 415V / 480V |
|
Frequency |
50Hz / 60Hz |
|
Engine Type |
4-Stroke Water-Cooled Diesel Engine |
|
Governor Type |
Electronic Governor |
|
Starting System |
24V DC Electric Start |
|
ATS Response Time |
≤10s |
|
Voltage Regulation |
±1% |
|
Frequency Regulation |
±0.25Hz |
|
THD Level |
≤5% |
|
Alternator Type |
Brushless Copper Alternator |
|
Insulation Class |
H Class |
|
Protection Grade |
IP23 / IP44 |
|
Cooling System |
Heavy-Duty Radiator |
|
Noise Level |
68–75dB at 7m |
|
Continuous Operation |
24-Hour Emergency Running |
|
Fuel Tank Capacity |
8–24 Hours Runtime |
|
Parallel Synchronization |
Available |
|
Controller Options |
Deep Sea / ComAp / SmartGen |
|
ATS Type |
Open / Closed Transition |
|
Remote Monitoring |
GSM / Ethernet Optional |
|
Compliance Standards |
ISO 8528 / IEC / CE |
Core Medical Equipment Power Reliability Technologies
Fast Emergency Startup
Coolant jacket heater maintains standby temperature at 40–50°C for ≤10s emergency startup response.
Stable Voltage Recovery
AVR-controlled alternator maintains voltage fluctuation within ±1% during sudden equipment startup impact.
Frequency Stability Control
Electronic governor limits frequency fluctuation within ±0.25Hz during rapid load variation.
Low Harmonic Output
Alternator winding structure reduces harmonic distortion affecting diagnostic and monitoring equipment.
Continuous Cooling Performance
Oversized radiator supports stable operation during long-duration hospital emergency loading.
ATS Coordination Function
Generator controller supports synchronized ATS startup and emergency load transfer operation.
ATS Emergency Transfer System
Utility Power Monitoring
ATS continuously monitors abnormal utility voltage and frequency conditions.
Automatic Generator Startup
Generator starts automatically after utility interruption detection.
Medical Equipment Load Transfer
Critical medical equipment circuits transfer after voltage stabilization.
Utility Recovery Re-Transfer
System automatically switches load back after utility stabilization.
ATS Modes Available
- Open Transition ATS
- Closed Transition ATS
- Delayed Transition ATS
Remote Monitoring Compatibility
Supports Ethernet and GSM remote monitoring systems.
Medical Equipment Load Stability
MRI Startup Load Handling
AVR reduces transient voltage dip during high inrush MRI startup conditions.
CT Scanner Power Stability
Electronic governor improves frequency recovery during sudden imaging equipment load variation.
Laboratory Equipment Protection
Low harmonic alternator output improves compatibility with precision medical analyzers.
Ventilator and Monitor Stability
Stable voltage output reduces interruption risk for life-support equipment.
Compliance & Factory Testing
Full Load Bank Testing
0–100% load testing completed before shipment.
ATS Transfer Simulation
Emergency startup and transfer operation tested during inspection.
Voltage Recovery Testing
Voltage stabilization performance verified under sudden load conditions.
Continuous Runtime Verification
Cooling performance and fuel stability monitored during extended operation testing.
Harmonic Output Inspection
Electrical output inspected for sensitive medical equipment compatibility.
Compliance Standards
- ISO 8528
- IEC Standards
- CE Certification
- Factory Quality Testing Procedures
Optional Configurations
|
Optional Item |
Available Options |
|
ATS System |
Open / Closed Transition |
|
Soundproof Canopy |
68dB / 75dB |
|
Fuel Tank |
Base / External Tank |
|
Controller Brand |
Deep Sea / ComAp / SmartGen |
|
Remote Monitoring |
GSM / Ethernet |
|
Synchronization System |
Parallel Operation |
|
Exhaust System |
Residential Silencer |
|
Cooling System |
High Ambient Radiator |
|
Circuit Breaker |
ABB / Schneider |
|
Trailer Type |
Mobile Trailer Optional |
Maintenance Accessibility
Side Service Access
Large maintenance doors improve inspection efficiency.
External Fuel Refill Port
Supports rapid fuel replenishment during emergency operation.
Modular Filter Layout
Fuel and oil filters designed for fast replacement.
Alarm History Recording
Controller stores operating alarms and shutdown records.
External Drain System
Oil and coolant drain layout reduces maintenance downtime.
FAQ