Product Overview
Hospital Silent Diesel Generator designed for hospitals, ICU buildings, inpatient wards, and medical facilities requiring low-noise emergency power supply, featuring soundproof canopy insulation, ≤10s automatic startup, and stable emergency power output during utility failure.
Technical Specifications
|
Item |
Specification |
|
Power Range |
20–2500kVA |
|
Rated Voltage |
220V / 380V / 400V / 415V / 480V |
|
Frequency |
50Hz / 60Hz |
|
Engine Type |
4-Stroke Water-Cooled Diesel Engine |
|
Governor Type |
Electronic Governor |
|
Starting System |
24V DC Electric Start |
|
ATS Response Time |
≤10s |
|
Voltage Regulation |
±1% |
|
Frequency Regulation |
±0.25Hz |
|
Noise Level |
68–75dB at 7m |
|
Alternator Type |
Brushless Copper Alternator |
|
Insulation Class |
H Class |
|
Protection Grade |
IP23 / IP44 |
|
Cooling System |
Heavy-Duty Radiator |
|
Fuel Tank Capacity |
8–24 Hours Runtime |
|
Continuous Operation |
24-Hour Emergency Running |
|
Soundproof Structure |
Acoustic Foam + Perforated Steel |
|
Exhaust System |
Residential Grade Silencer |
|
Controller Options |
Deep Sea / ComAp / SmartGen |
|
ATS Type |
Open / Closed Transition |
|
Remote Monitoring |
GSM / Ethernet Optional |
|
Compliance Standards |
ISO 8528 / CE / IEC |
Core Silent Operation Technologies
Multi-Layer Soundproof Canopy
Canopy structure combines acoustic insulation cotton, perforated steel lining, and sealed access doors to reduce operational noise.
Residential Grade Exhaust Silencer
Multi-chamber exhaust silencer reduces high-frequency exhaust noise during full-load operation.
Low-Vibration Base Frame
Integrated anti-vibration mounts reduce engine vibration transmission to surrounding structures.
Controlled Cooling Airflow
Air intake and exhaust channels designed with airflow redirection to reduce fan noise output.
Stable Emergency Startup
Coolant jacket heater maintains standby temperature at 40–50°C for ≤10s startup response.
Voltage Stability Control
AVR-controlled alternator maintains voltage fluctuation within ±1% during sudden hospital load transfer.
ATS Emergency Transfer System
Utility Failure Detection
ATS continuously monitors abnormal voltage and frequency conditions.
Automatic Generator Startup
Generator automatically starts after utility interruption detection.
Emergency Load Transfer
Hospital emergency circuits transfer after voltage stabilization.
Utility Recovery Switching
System automatically transfers load back after stable utility restoration.
ATS Modes Available
- Open Transition ATS
- Closed Transition ATS
- Delayed Transition ATS
Remote Monitoring Integration
Supports remote ATS and generator monitoring through GSM or Ethernet communication.
Low Noise & Load Stability Performance
Ward Area Noise Reduction
Acoustic canopy structure reduces operational noise around patient treatment areas.
ICU Equipment Power Stability
Electronic governor improves frequency recovery during sudden ICU equipment startup.
HVAC Emergency Load Handling
Stable voltage recovery improves operation during hospital air handling system startup.
Continuous Quiet Operation
Cooling airflow structure reduces noise increase during long-duration operation.
Compliance & Factory Testing
Noise Level Testing
Generator noise levels tested at 7-meter distance before shipment.
Full Load Bank Testing
0–100% load simulation completed during factory inspection.
ATS Transfer Simulation
Automatic startup and emergency transfer operation verified before delivery.
Continuous Runtime Verification
Cooling temperature and fuel stability monitored during extended operation testing.
Vibration Inspection
Base frame and canopy vibration levels inspected during operation testing.
Compliance Standards
- ISO 8528
- IEC Standards
- CE Certification
- Factory Quality Inspection Procedures
Optional Configurations
|
Optional Item |
Available Options |
|
ATS System |
Open / Closed Transition |
|
Soundproof Level |
68dB / 75dB |
|
Fuel Tank |
Base / External Tank |
|
Controller Brand |
Deep Sea / ComAp / SmartGen |
|
Remote Monitoring |
GSM / Ethernet |
|
Synchronization System |
Parallel Operation |
|
Exhaust System |
Residential / Industrial Silencer |
|
Cooling System |
High Ambient Radiator |
|
Circuit Breaker |
ABB / Schneider |
|
Trailer Type |
Mobile Trailer Optional |
Maintenance Accessibility
Large Side Access Doors
Simplifies daily inspection and servicing procedures.
External Fuel Refill Port
Supports rapid fuel replenishment during emergency operation.
Modular Acoustic Panels
Removable soundproof panels improve maintenance accessibility.
Alarm History Recording
Controller stores operating alarms and shutdown records.
External Drain Layout
Oil and coolant drain points reduce maintenance time.
FAQ
Hot Tags: hospital silent diesel generator, China hospital silent diesel generator manufacturers, suppliers, factory